summary
Analysis of CODIS and Pronos runtimes shows no authentication on ladder-logic uploads, allowing arbitrary recipe replacement and root-level code execution via uploaded binaries; a directory-traversal flaw exposes any file on the controller. Version 3’s UDP protocol uses a two‑byte session ID that effectively has ~16,000 values so it can be brute‑forced, and a packet byte indexes CRC/function pointers enabling remote code execution. Scans (nmap/Unicorn/Shodan) find ~2,200 exposed devices; fixes require OEM firmware updates and many vendors remain unpatched.
AI-written summary · about
chapters (15)
- 0:00Introduction to talk
- 1:02Defining vulnerabilities
- 2:44Third-party libraries in PLCs
- 3:26CODIS library overview
- 7:19CODIS version two flaws
- 11:47Vendor response to CODIS issues
- 13:11CODIS version three protocol
- 18:34Exploiting CODIS version three
- 21:00Vendor advisories and inaccuracies
- 23:51Hitachi and Sano Deni controllers
- 27:44Pronos library vulnerabilities
- 29:51Iranian PLC with Pronos
- 31:18Scanning for vulnerable PLCs
- 33:23Government role in vulnerability mitigation
- 35:26Conclusions and vendor challenges