The PX4 Airspeed Pipeline
summary
Follows the PX4 pipeline from pitot reading to controller use: differential_pressure -> IAS -> CAS -> TAS is computed per sensor, a per‑sensor airspeed scale learned by wind estimator after full circle is stored and applied, and validity is gated by five validator checks (data missing, stuck, innovation, load factor, first principles). Controllers either use calibrated airspeed for forces (rate controller scales outputs by trim_speed / calibrated_airspeed squared) or true airspeed for kinematics; if no valid sensor exists, PX4 falls back to running without airspeed.