A study with 20 participants compares a wrist-worn tactile display of 10-actuator wristband cues in two reference frames and measures accuracy, reaction time, and cognitive load across 120 trials per participant per condition. Allocentric cues yield no accuracy change (84% vs 85%, 28.5° vs 26.8° mean error) but produce 240 ms faster reaction time and 38% reduction in cognitive load (Raw TLX, large effect on mental demand), and remain robust to wrist rotation.