Mindless Load Changer: A Method for Manipulating Load Perception by Feedback of Myoelectricity ...
summary
A prototype system displays modified myoelectric readings from a myoelectricity sensor on the biceps as 10 gage blocks, with values multiplied by 1.5 or 0.5 to simulate high or low load. Participants lift 1.5 kg luggage while watching the display; perceived weight shifts toward the shown value by about 10% (≈140 g) on average and up to 30% (≈500 g). Individual responses split: 62% match the manipulation, 23% reverse, 15% show no effect.