Ultra-Low Latency SSDs' Impact on Overall Energy Efficiency
Talkat 12th USENIX Workshop on Hot Topics in Storage and File Systems (HotStorage '20) · 2020-07-13..07-14
summary
Empirical study measures an Intel Optane SSD alongside an HDD and two flash SSDs on a 1U Dell using an inline plug power meter and fio workloads and shows Optane eats more peak power yet yields the best energy proportionality spanning >50% of peak system power and the highest bytes-per-joule and IOPS-per-joule. Tiny 1 KB requests are highly inefficient, Optane saturates with limited internal parallelism so deeper queues stop improving efficiency, and interrupts spike to ~600,000 interrupts/sec and drive ~300% CPU at ~400,000 interrupts for writes.
AI-written summary · about
chapters (14)
- 0:00UNIVERSITY OF LOUISVILLE
- 0:30What is Ultra-Low Latency (ULL) data access?
- 0:55What is Optane SSD?
- 1:16Motivation
- 2:12Test devices
- 2:37Experimental setup
- 3:20Idle vs. active power consumption
- 5:06Read vs. write power consumption Observation 3 Newer storage generations have greater differences in power consumption between reads and writes
- 5:55Energy proportionality
- 7:33Impact on system software
- 9:30Overall energy efficiency metrics
- 9:55Impact on overall energy efficiency Observation 6
- 11:27Conclusion
- 11:52Discussion and future research