summary
Project targets ISO 26262 / IEC 61508 SIL3 certification for ARM64 and x86 and already holds a concept approval letter; work focuses on shrinking the certifiable footprint and closing coverage gaps. Build changes add -ffunction-sections and -fdata-sections plus a linker GC pass and an audit tool that trims coverage notes so reports match shipped binaries. About 3,000 lines drop from hypercore dispatches via a const/jump-filter pattern; testing uses four vehicles — domain tests, QEMU qtest, self-tests and GDB fault injection — and reports no blocker to 100% coverage.
AI-written summary · about
chapters (14)
- 0:00Introduction and team overview
- 1:02Safety certification goals and challenges
- 2:47Code removal and upstream alignment
- 6:44Garbage collection for dead code
- 10:18Techniques for fine-grained code reduction
- 13:07Freedom from interference in Xen
- 16:58Domain isolation and capabilities
- 18:25Testing framework and methodologies
- 22:41Issues found and upstream contributions
- 24:25Real-time systems and MPU upstreaming
- 26:32Collaboration with safety projects
- 27:35Summary and community impact
- 28:39Q&A: Test vehicles and testing methodologies
- 29:21Q&A: Hardware domain interference