Xen Automotive Safety Certification Lessons
summary
An 18‑month effort defines a practical ASIL B scope for Xen 4.22 SVA, limits verification to QEMU simulation initially and plans target hardware testing in 2027, and produces ~1000 requirements tied to about 200–300k LOC and roughly a hundred test cases. Tooling includes Electool for MISRA checks, Open Fast plus an Excel traceability matrix, and a homegrown MCDC tool from QEMU traces because GCC coverage is insufficient. Major risks: keeping traceability current as Xen evolves and limited engineers with both hypervisor and safety skills.
AI-written summary · about
chapters (18)
- 0:00Introduction to Xen in automotive
- 3:08Automotive hypervisor requirements
- 5:43Qualification strategy for Xen
- 7:54Collaboration for safety artifacts
- 9:39Creating SEOC definition
- 11:21Product and safety requirements
- 13:26Architectural design implementation
- 14:11Safety analysis DFMEA and DFA
- 19:05Hypervisor support implementation
- 20:36Verification methods and challenges
- 21:57Traceability in qualification
- 23:39Integration and usage assumptions
- 25:01Tool qualification process
- 26:45Safety case and justification
- 28:12Independent assessment process
- 29:16Key lessons learned
- 32:22Project summary and next steps
- 32:43Q&A session