Intrinsically Safe Circuits
summary
Covers how intrinsic safety is implemented in practice: applying standard energy budgets (e.g., capacitor limits of 1.41 µF at 12 V), using design tactics such as three-way redundancy and diode clamps to keep node voltages ≤5 V, and choosing between pressurised enclosures, potting, or intrinsic safety with their tradeoffs. Shows concrete KiCad workflows used to support these designs: hierarchical schematics, net labels and net classes mapped to 2 mm wide traces for non-failable conductors, BOM export to CSV, 3D clearance screenshots, and points out where tool checks do not fully enforce the rules.