Demonstrates a practical break of S7CommPlus by reverse‑debugging the Siemens client binary to recover three proprietary encryptions, one simple XOR chain and a session‑ID based function cipher, then implements those routines in a small program and uses Wireshark captures to control an S7‑1200 (HW v4.1) PLC (stop/run shown). Replay attacks originally fail until the ciphers are reproduced. Suggests fixes: anti‑debug, optional PLC password and full‑packet encryption.