Generating a New Indoor Radon Risk Map
summary
A new, higher-resolution indoor radon risk map for Ireland is generated, testing over 70 modeling routines (logistic regression baseline, decision tree, random forest, bagging and boosting) and using 32,000 measurements (later ~40,000) with only twelve positives, which drives heavy sampling. Models are tuned by precision–recall AUC and subjected to spatial cross-validation with 0–10 km buffers (five-fold) to track performance decline with distance. Bagging with edited nearest neighbor scores highest but logistic regression is adopted for calibrated, programmatic outputs; the pipeline is automated and the map is ready for publication.
AI-written summary · about
chapters (12)
- 0:00Introduction to radon mapping
- 1:11Need for a new radon risk map
- 3:15Study aims and background
- 4:18Approach and data considerations
- 5:21Model selection and metrics
- 6:47Sampling strategies for imbalance
- 7:50Standard cross-validation results
- 8:56Spatial cross-validation method
- 10:21Spatial CV results and analysis
- 12:05Final model performance comparison
- 13:33Map progression and final output
- 15:00Q&A session