I have a dumb theory but I can't find any counter example
summary
A production launch faces rising latency traced by a quick Prometheus + EC2 API script that shows a clear split: odd vs even IPs—odd-addressed reverse proxies degrade and never recover. Root cause is an upstream F5 partitioning by source IP combined with a bad SFP fiber module causing millions of CRC errors, dropping packets and triggering TCP retry storms. Mitigation redeploys proxies to shift traffic and waits for VA networking to replace the module; launch then proceeds successfully.
AI-written summary · about
chapters (12)
- 0:00Introduction and background
- 1:28VA.gov redesign project
- 3:16Hybrid migration approach
- 5:47Latency spike incident
- 7:32Investigating proxy differences
- 9:18Odd and even IP addresses
- 11:04Upstream hardware failure
- 13:54Mitigation and resolution
- 14:38Launch success and lessons
- 16:03Monitoring and automation
- 18:54Diluted responsibility issue
- 20:02Q&A session