Open vSwitch works in production with recent encapsulation features and measured kernel-module latency overhead under <10% latency versus native paths; added tunnel-in-tunneling to scale many remote endpoints and implemented fixes for GRE aggregation and mega-flow interaction. Major pain points are repository fragmentation (kernel.org vs openvswitch.org), integration with iptables/netfilter and connection tracking causing a 90% slowdown on connection-rate tests (CRR) until patched, plus fragmented-packet/PMTU handling that required workarounds.
AI-written summary · about
chapters (11)
- 0:00Introduction to Open vSwitch
- 1:49Open vSwitch strengths and adoption
- 4:00Performance and kernel module details
- 6:42Tunneling improvements and scalability
- 9:08Flow table issues and connection tracking
- 14:33Flow matching and configuration challenges
- 17:15Path MTU discovery and fragmentation
- 21:13TTL and flow entry explosion
- 24:53Integration with iptables and limitations
- 27:49GRE support and performance fixes
- 28:53Performance testing and tools