OvS Tunneling and Connection Tracking Hardware Offload via Rte_flow
summary
Describes a concrete OvS‑DPDK path: an exact‑match flow flattening cache that records CT session and NAT pointers and cuts header parsing and lookups by about 50%, a best‑effort partial offload via DPDK rte_flow and a prototype VXLAN acceleration on Intel E810, plus a SmartNIC full offload that uses rte_flow_action_type_jump and vport→lan_port mapping to merge flow chains and eliminate recirculation so the CT state machine can be split between hardware and software.
AI-written summary · about
chapters (13)
- 0:00Introduction to OvS-DPDK offload
- 1:11Partial offload status quo
- 5:28Flow flattening cache concept
- 9:46FFC generation process
- 14:53Hardware acceleration with FFC
- 17:18Full offload with SmartNIC
- 19:31Tunnel acceleration in OvS
- 23:46Tunnel decap process
- 26:03Connection tracking overview
- 27:59Full offload challenges
- 30:00Recirculation and flow chain
- 31:28CT state machine offload
- 33:03Q&A and discussion