Integrates ARM’s software test library via Trusted Firmware so tests run STL at EL3 rather than inside the kernel, invoked from Linux through a character device and SMC, with per-core user‑space test processes scheduled to meet a fault‑tolerance time interval. Uses STPA and the RAFIA workflow (risk analysis, fault injection, automation) to derive tests and evidence, and a deterministic construction service for reproducible builds and ISO 26262 tool qualification. Prototype runs on a Raspberry Pi 4 and highlights GPL vs commercial license friction, qualified‑tool issues, and pathways for system‑level certification.

AI-written summary · about

  1. 0:00Introduction
  2. 1:54Pauls background
  3. 3:19What is safety
  4. 3:43Safety mechanism
  5. 4:28What is safe
  6. 6:41Additional perceived challenges
  7. 7:44raffia
  8. 9:31Overview
  9. 10:29What is a Safety Test Library
  10. 12:10Technical Challenges
  11. 14:02Software License Restrictions
  12. 15:31Integrate STL with Linux
  13. 20:39Integrate into a reference system
  14. 22:32Safety related system
  15. 26:43Conclusion